Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (2024)

  • Speed up cycle times

    With Lisa Mini all load types can be sterilized. Thanks to the different cycles, it is possible to reprocess any instrument, wrapped or unwrapped, with extremely short cycle times.
    In addition, the sterilizer offers one of the fastest type B cycles in its performance class.

    Thanks to the optimised cycle profile, wrapped instruments like handpieces can be sterilized in less than 18 minutes. Unwrapped loads can be sterilized in less than 9 minutes.

    Wrapped: 17' 45''
    Unwrapped: 8' 45''

    Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (1)

    • Wide range of applications

      Speed up flexibility

      Take advantage of Lisa Mini‘s flexibility. Thanks to its small dimensions, Lisa Mini can be easily positioned in the reprocessing room. Moreover, it offers the possibility to stack items on top. Thus, Lisa Mini offers a wide range of applications, e.g., as a complementary device for the fast reprocessing of instruments, e.g. handpieces, and as emergency back-up of tabletop sterilizers.

    • Chamber sizes

      High load flexibility

      Lisa Mini is available with a chamber size of either 3 litres or 5 litres:

      With the 3 litre chamber, Lisa Mini can reprocess up to 1 kg of load, which corresponds to up to 15 handpieces.

      In the 5 litre version, it is 1.5 kg, which corresponds to up to 22 handpieces.

    • Trays and cassettes

      Even more flexibility

      The devices come along with 2 trays, an optional 3-tray accessory is available for even more loading flexibility.

      Lisa Mini also offers space for two 5-instruments cassettes in the 3 litre version, and four 5-instruments cassettes or two 10-instruments cassettes in the 5 litre version.

      Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (2)

      • Traceability

        Speed up traceability

        The technical expertise makes the difference. The Lisa Mini sterilizer is based on a sophisticated technical concept that offers future-oriented possibilities and significantly simplifies your workflow.

      • Documentation

        Enhanced traceability

        The documentation is automatically saved via a high-capacity USB stick.

        The barcode label printer provides additional support on traceability thanks to the opportunity for linking cycle, sterilization package and patient.

        The cycle report printer ensures adequate paper documentation of the cycle.

        Wi-Fi and LAN connections offer the possibility to download cycle reports directly to any PC or smart device.

        Advanced connectivity

        The ioDent® system offers intelligent dental solutions and enables an advanced service support.

        W&H Steri App

        The W&H Steri App is an advanced smartphone and tablet application that allows controlling and remote monitoring of the sterilizer in your dental clinic. Moreover, cycle history back-up automatically saved on smartphone ensures extra-safety.

        Compatibility:

        The application is compatible with all sterilizers currently available.
        Available languages: EN, IT, FR, DE, ES, ZH-CN, JP

        Main features:

        Remote control of your sterilizer: the user can remotely command up to 4 sterilizers.
        Advanced traceability: EliTrace feature is now fully supported and the App permits to create instrument database directly from your smart device. In addition to this function, the management and tracking of dental instruments is integrated.
        Reports creation: the App allows making intervention reports in order to collect data regarding specific treatments.
        User management: creation and handling of sterilizer users directly from your smart device.
        Backup functionality: all the cycle reports are automatically saved to assure more protection of data.

        • Speed up with Activation Codes

          Needs and requirements may change. Prepare yourself now: With the Activation Code system, additional functions can be activated to meet your changing practice needs and future requirements.

          With the EliTrace feature, the sterilization process can be traced and documented down to the individual instrument or kit. Without any additional software or computer.

          More about EliTrace

          Six steps to your customised sterilizer:

          1. Purchase the Activation Code of your choice from your local approved dental supplier.
          2. After receiving the related login code, go to activation.wh.com
          3. Specify this code along with the serial number and model of your sterilizer.
          4. Your individual, secure Activation Code is generated.
          5. Enter this code in the menu of your sterilizer.
          6. The feature is available.
          • Intuitive menus

            Speed up daily tasks

            The Lisa Mini touch screen with intuitive menus offers a wide range of options to meet all your needs.

            Simple cycle selection: switched on, the home screen immediately displays the cycle selection.

            Risk-free cycle selection: thanks to the possibility of customising the start screen with only the sterilization cycles sed, daily activities are simplified.

            User guidance: instruction is available with the help button in order to assist you during navigation.

            Guided maintenance: a set of 3-D animations shows you the main maintenance operations step by step. This makes operation easy and straightforward.

          • Reduced maintenance

            Convincing arguments

            Quality, reliability and reduced maintenance:

            The maintenance interval of the Lisa Mini sterilizer is 4,000 cycles or 5 years thanks to high-quality components.

          • Automatic water filling

            Easy filling

            The automatic water filling makes the handling convenient:

            An integrated funnel prevents water splashes during the filling process.

            An automatic water filling valve allows you to connect a demineralization system.

            Manual filling and draining are no longer necessary.

            Appropriate accessories

            Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (4)

            Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (5)

            Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (6)

            Sprint

            Print out cycle protocols on thermal paper with 10-year paper guarantee. More Info!

            Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (7)

            Multidem

            Multidem supplies demineralized water for steam generation and can be used for many conventional sterilizers and processing units. As a result, it ensures consistent and optimised performance, thereby extending the service life of your sterilizer. More Info!

            Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (8)

            Barcode scanner

            This enables you to scan labels into patient files.

            Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (9)

            Helix Test

            The Helix test ensures optimum process control for type B sterilizers. The QR code on the test strips enables full traceability and easy use with eLog, the digital logbook.
            More Info!

            Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (10)

            Barcode label printer

            The label printer can be connected to the sterilizer to print barcodes. In combination with the integrated data logger, it improves your traceability system. The label printer is a quick and easy tool to link the sterilization cycle with patient files.
            More Info!

            • Environmentally friendly packaging

              The environmentally friendly packaging is completely reusable and recyclable. Plastic components were reduced to a minimum. For 99% of its weight, the new package is made of cardboard and other fully biodegradable substances.

              W&H AIMS hygiene workflow

              Sterilization, hygiene, and maintenance are increasingly important in the dental practice. The new Lisa Mini is an optimally matching part of W&H´s wide range of products for the safe reprocessing of instruments, contra-angle and turbine handpieces according to the recommended, holistic W&H AIMS hygiene workflow.

              W&H AIMS

              Product & consumables

              Lisa Mini sterilizer, 3 litres

              supplied with 2 aluminium trays, drain hose, tray holder, 8 GB USB stick, door opening tool, factory test, compressed air tube,
              50/60 Hz

              Lisa Mini RIS-303 (220 V)
              REF 19944100

              Chamber size 3 litre, compressed air

              Lisa Mini RIS-303 (110 V)
              REF 19944200

              Chamber size 3 litre, compressed air

              Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (14) Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (15)

              Request price

              Lisa Mini sterilizer, 5 litres

              supplied with 2 aluminium trays, drain hose, tray holder, 8 GB USB stick, door opening tool, factory test, compressed air tube,
              50/60 Hz

              Lisa Mini RIS-305 (220 V)
              REF 19945100

              Chamber size 5 litre, compressed air

              Lisa Mini RIS-305 (220 V)
              REF 19935100

              Chamber size 5 litre, vacuum pump

              Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (19) Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (20)

              Request price

              Download Area

              FAQ

              • Who should I contact to validate and maintain my sterilizer?
              • Does my sterilizer need any periodic qualification/validation?
              • How long should I archive the documentation of regular tests?
              • Do I need to document the results of all periodic tests?
              • Should I pouch/wrap my instruments and how long can I store them after sterilization?
              • What is validation?
              • Which water quality should I use for my sterilizer?
              • How do I change consumable components on my sterilizer?
              • What is the maximum noise level of the Lisa Mini sterilizer?
              • How do I clean the water tank and what products should I use?
              • Is Lisa Mini requiring compressed air connection?

              more

              Instructions for use

              Find all languages of the Update Hygiene and Maintenance (EN ISO 17664:2017) in the Download Centre.

              Videos & Tutorials

              For a seamless and interactive online experience of our multimedia content (e.g. videos, maps), please accept the storage of the necessary cookies (YouTube, MovingImage - detailed information on these cookies can be found in the imprint/data protection) for marketing purposes.

              Accept

              Lisa Mini, W&H type B sterilizer for fast handpiece reprocessing (2024)
              Top Articles
              Latest Posts
              Article information

              Author: Pres. Lawanda Wiegand

              Last Updated:

              Views: 6672

              Rating: 4 / 5 (51 voted)

              Reviews: 90% of readers found this page helpful

              Author information

              Name: Pres. Lawanda Wiegand

              Birthday: 1993-01-10

              Address: Suite 391 6963 Ullrich Shore, Bellefort, WI 01350-7893

              Phone: +6806610432415

              Job: Dynamic Manufacturing Assistant

              Hobby: amateur radio, Taekwondo, Wood carving, Parkour, Skateboarding, Running, Rafting

              Introduction: My name is Pres. Lawanda Wiegand, I am a inquisitive, helpful, glamorous, cheerful, open, clever, innocent person who loves writing and wants to share my knowledge and understanding with you.